The effects of area contraction on the performance of UNITEN's shock tube

Numerical study

A. M. Mohsen, Mohd Zamri Yusoff, A. Al-Falahi

Research output: Contribution to journalConference article

Abstract

Numerical study into the effects of area contraction on shock tube performance has been reported in this paper. The shock tube is an important component of high speed fluid flow test facility was designed and built at the Universiti Tenaga Nasional (UNITEN). In the above mentioned facility, a small area contraction, in form of a bush, was placed adjacent to the diaphragm section to facilitate the diaphragm rupturing process when the pressure ratio across the diaphragm increases to a certain value. To investigate the effects of the small area contraction on facility performance, numerical simulations were conducted at different operating conditions (diaphragm pressure ratios P4/P1 of 10, 15, and 20). A two-dimensional time-accurate Navier-Stokes CFD solver was used to simulate the transient flow in the facility with and without area contraction. The numerical results show that the facility performance is influenced by area contraction in the diaphragm section. For instance, when operating the facility with area contraction using diaphragm pressure ratio (P4/P1) of 10, the shock wave strength and shock wave speed decrease by 18% and 8% respectively.

Original languageEnglish
Article number012111
JournalIOP Conference Series: Earth and Environmental Science
Volume16
Issue number1
DOIs
Publication statusPublished - 01 Jan 2013
Event26th IAHR Symposium on Hydraulic Machinery and Systems - Beijing, China
Duration: 19 Aug 201223 Aug 2012

Fingerprint

contraction
shock wave
transient flow
fluid flow
effect
simulation
speed

All Science Journal Classification (ASJC) codes

  • Earth and Planetary Sciences(all)
  • Environmental Science(all)

Cite this

@article{f9e4bd42ce4d411881dbf1bc874e01a4,
title = "The effects of area contraction on the performance of UNITEN's shock tube: Numerical study",
abstract = "Numerical study into the effects of area contraction on shock tube performance has been reported in this paper. The shock tube is an important component of high speed fluid flow test facility was designed and built at the Universiti Tenaga Nasional (UNITEN). In the above mentioned facility, a small area contraction, in form of a bush, was placed adjacent to the diaphragm section to facilitate the diaphragm rupturing process when the pressure ratio across the diaphragm increases to a certain value. To investigate the effects of the small area contraction on facility performance, numerical simulations were conducted at different operating conditions (diaphragm pressure ratios P4/P1 of 10, 15, and 20). A two-dimensional time-accurate Navier-Stokes CFD solver was used to simulate the transient flow in the facility with and without area contraction. The numerical results show that the facility performance is influenced by area contraction in the diaphragm section. For instance, when operating the facility with area contraction using diaphragm pressure ratio (P4/P1) of 10, the shock wave strength and shock wave speed decrease by 18{\%} and 8{\%} respectively.",
author = "Mohsen, {A. M.} and Yusoff, {Mohd Zamri} and A. Al-Falahi",
year = "2013",
month = "1",
day = "1",
doi = "10.1088/1755-1315/16/1/012111",
language = "English",
volume = "16",
journal = "IOP Conference Series: Earth and Environmental Science",
issn = "1755-1307",
publisher = "IOP Publishing Ltd.",
number = "1",

}

The effects of area contraction on the performance of UNITEN's shock tube : Numerical study. / Mohsen, A. M.; Yusoff, Mohd Zamri; Al-Falahi, A.

In: IOP Conference Series: Earth and Environmental Science, Vol. 16, No. 1, 012111, 01.01.2013.

Research output: Contribution to journalConference article

TY - JOUR

T1 - The effects of area contraction on the performance of UNITEN's shock tube

T2 - Numerical study

AU - Mohsen, A. M.

AU - Yusoff, Mohd Zamri

AU - Al-Falahi, A.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Numerical study into the effects of area contraction on shock tube performance has been reported in this paper. The shock tube is an important component of high speed fluid flow test facility was designed and built at the Universiti Tenaga Nasional (UNITEN). In the above mentioned facility, a small area contraction, in form of a bush, was placed adjacent to the diaphragm section to facilitate the diaphragm rupturing process when the pressure ratio across the diaphragm increases to a certain value. To investigate the effects of the small area contraction on facility performance, numerical simulations were conducted at different operating conditions (diaphragm pressure ratios P4/P1 of 10, 15, and 20). A two-dimensional time-accurate Navier-Stokes CFD solver was used to simulate the transient flow in the facility with and without area contraction. The numerical results show that the facility performance is influenced by area contraction in the diaphragm section. For instance, when operating the facility with area contraction using diaphragm pressure ratio (P4/P1) of 10, the shock wave strength and shock wave speed decrease by 18% and 8% respectively.

AB - Numerical study into the effects of area contraction on shock tube performance has been reported in this paper. The shock tube is an important component of high speed fluid flow test facility was designed and built at the Universiti Tenaga Nasional (UNITEN). In the above mentioned facility, a small area contraction, in form of a bush, was placed adjacent to the diaphragm section to facilitate the diaphragm rupturing process when the pressure ratio across the diaphragm increases to a certain value. To investigate the effects of the small area contraction on facility performance, numerical simulations were conducted at different operating conditions (diaphragm pressure ratios P4/P1 of 10, 15, and 20). A two-dimensional time-accurate Navier-Stokes CFD solver was used to simulate the transient flow in the facility with and without area contraction. The numerical results show that the facility performance is influenced by area contraction in the diaphragm section. For instance, when operating the facility with area contraction using diaphragm pressure ratio (P4/P1) of 10, the shock wave strength and shock wave speed decrease by 18% and 8% respectively.

UR - http://www.scopus.com/inward/record.url?scp=84881137989&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881137989&partnerID=8YFLogxK

U2 - 10.1088/1755-1315/16/1/012111

DO - 10.1088/1755-1315/16/1/012111

M3 - Conference article

VL - 16

JO - IOP Conference Series: Earth and Environmental Science

JF - IOP Conference Series: Earth and Environmental Science

SN - 1755-1307

IS - 1

M1 - 012111

ER -