The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe

A. B.A. Ghani, C. K. Chakrabarty

Research output: Contribution to conferencePaper

3 Citations (Scopus)

Abstract

Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable.

Original languageEnglish
Pages444-447
Number of pages4
DOIs
Publication statusPublished - 31 Dec 2008
Event2008 International Symposium on Electrical Insulating Materials, ISEIM 2008 - Yokkaichi, Japan
Duration: 07 Sep 200811 Sep 2008

Other

Other2008 International Symposium on Electrical Insulating Materials, ISEIM 2008
CountryJapan
CityYokkaichi
Period07/09/0811/09/08

Fingerprint

Partial discharges
Cables
Magnetic fields
Electromagnetic fields
Insulation
Polyethylene
Polyethylenes
Bandwidth
Degradation
Air

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials

Cite this

Ghani, A. B. A., & Chakrabarty, C. K. (2008). The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe. 444-447. Paper presented at 2008 International Symposium on Electrical Insulating Materials, ISEIM 2008, Yokkaichi, Japan. https://doi.org/10.1109/ISEIM.2008.4664581
Ghani, A. B.A. ; Chakrabarty, C. K. / The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe. Paper presented at 2008 International Symposium on Electrical Insulating Materials, ISEIM 2008, Yokkaichi, Japan.4 p.
@conference{e8c055499e6e4942bc422cf95b37d336,
title = "The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe",
abstract = "Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable.",
author = "Ghani, {A. B.A.} and Chakrabarty, {C. K.}",
year = "2008",
month = "12",
day = "31",
doi = "10.1109/ISEIM.2008.4664581",
language = "English",
pages = "444--447",
note = "2008 International Symposium on Electrical Insulating Materials, ISEIM 2008 ; Conference date: 07-09-2008 Through 11-09-2008",

}

Ghani, ABA & Chakrabarty, CK 2008, 'The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe', Paper presented at 2008 International Symposium on Electrical Insulating Materials, ISEIM 2008, Yokkaichi, Japan, 07/09/08 - 11/09/08 pp. 444-447. https://doi.org/10.1109/ISEIM.2008.4664581

The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe. / Ghani, A. B.A.; Chakrabarty, C. K.

2008. 444-447 Paper presented at 2008 International Symposium on Electrical Insulating Materials, ISEIM 2008, Yokkaichi, Japan.

Research output: Contribution to conferencePaper

TY - CONF

T1 - The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe

AU - Ghani, A. B.A.

AU - Chakrabarty, C. K.

PY - 2008/12/31

Y1 - 2008/12/31

N2 - Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable.

AB - Partial discharge is a well known phenomenon that caused insulation degradation in cross-linked polyethylene power cable. Thus eventually will cause insulation failure. When partial discharge occurs, it radiates electromagnetic field in all direction. This electromagnetic field has a bandwidth of about 1GHz at source. This paper hence describes the design of a simple single layer air-core coil as inductive probe to detect the presence of magnetic field components due to partial discharge. It is shown that, it is possible to detect the presence of PD at 1m away from the cable.

UR - http://www.scopus.com/inward/record.url?scp=58049117324&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58049117324&partnerID=8YFLogxK

U2 - 10.1109/ISEIM.2008.4664581

DO - 10.1109/ISEIM.2008.4664581

M3 - Paper

AN - SCOPUS:58049117324

SP - 444

EP - 447

ER -

Ghani ABA, Chakrabarty CK. The detection of magnetic field from Partial Discharge (PD) signal in XLPE cable using inductive probe. 2008. Paper presented at 2008 International Symposium on Electrical Insulating Materials, ISEIM 2008, Yokkaichi, Japan. https://doi.org/10.1109/ISEIM.2008.4664581