Stability of erbium-doped fiber laser for high pressure measurement

Ring vs linear cavity

Fairuz Abdullah, Sumayyah Mohd Idris, Mohammed Hayder Al-Mansoori, Md Zaini Jamaludin

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The application of optical fiber sensor in fields such as heavy industries has to greater extent become very important as the optical sensors is immune to EMI. This paper presented a stable high pressure sensor using an erbium-doped fiber laser (EDFL). The pressure sensor head is made of fiber Bragg grating (FBG) encased in stainless steel housing to withstand high pressure of up to 10bar. The stability of the sensing system is measured over 30 minutes and the result shows about 1.50% and 0.41% variation of peak output power for ring and linear respectively. In addition, the wavelength variation for ring is 1.16% and there is no significant variation linear configuration.

Original languageEnglish
Title of host publicationProceeding, 2010 IEEE Student Conference on Research and Development - Engineering
Subtitle of host publicationInnovation and Beyond, SCOReD 2010
Pages307-309
Number of pages3
DOIs
Publication statusPublished - 2010
Event2010 8th IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010 - Kuala Lumpur, Malaysia
Duration: 13 Dec 201014 Dec 2010

Other

Other2010 8th IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010
CountryMalaysia
CityKuala Lumpur
Period13/12/1014/12/10

Fingerprint

European Monetary Institute
heavy industry
Erbium
Pressure sensors
Fiber lasers
Pressure measurement
housing
Optical sensors
Fiber optic sensors
Fiber Bragg gratings
Stainless steel
Wavelength
Industry

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Education

Cite this

Abdullah, F., Idris, S. M., Al-Mansoori, M. H., & Jamaludin, M. Z. (2010). Stability of erbium-doped fiber laser for high pressure measurement: Ring vs linear cavity. In Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010 (pp. 307-309). [5704022] https://doi.org/10.1109/SCORED.2010.5704022
Abdullah, Fairuz ; Idris, Sumayyah Mohd ; Al-Mansoori, Mohammed Hayder ; Jamaludin, Md Zaini. / Stability of erbium-doped fiber laser for high pressure measurement : Ring vs linear cavity. Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010. 2010. pp. 307-309
@inproceedings{27ddec1a1bc34fc1856f0cfab0d9c945,
title = "Stability of erbium-doped fiber laser for high pressure measurement: Ring vs linear cavity",
abstract = "The application of optical fiber sensor in fields such as heavy industries has to greater extent become very important as the optical sensors is immune to EMI. This paper presented a stable high pressure sensor using an erbium-doped fiber laser (EDFL). The pressure sensor head is made of fiber Bragg grating (FBG) encased in stainless steel housing to withstand high pressure of up to 10bar. The stability of the sensing system is measured over 30 minutes and the result shows about 1.50{\%} and 0.41{\%} variation of peak output power for ring and linear respectively. In addition, the wavelength variation for ring is 1.16{\%} and there is no significant variation linear configuration.",
author = "Fairuz Abdullah and Idris, {Sumayyah Mohd} and Al-Mansoori, {Mohammed Hayder} and Jamaludin, {Md Zaini}",
year = "2010",
doi = "10.1109/SCORED.2010.5704022",
language = "English",
isbn = "9781424486489",
pages = "307--309",
booktitle = "Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering",

}

Abdullah, F, Idris, SM, Al-Mansoori, MH & Jamaludin, MZ 2010, Stability of erbium-doped fiber laser for high pressure measurement: Ring vs linear cavity. in Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010., 5704022, pp. 307-309, 2010 8th IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010, Kuala Lumpur, Malaysia, 13/12/10. https://doi.org/10.1109/SCORED.2010.5704022

Stability of erbium-doped fiber laser for high pressure measurement : Ring vs linear cavity. / Abdullah, Fairuz; Idris, Sumayyah Mohd; Al-Mansoori, Mohammed Hayder; Jamaludin, Md Zaini.

Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010. 2010. p. 307-309 5704022.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Stability of erbium-doped fiber laser for high pressure measurement

T2 - Ring vs linear cavity

AU - Abdullah, Fairuz

AU - Idris, Sumayyah Mohd

AU - Al-Mansoori, Mohammed Hayder

AU - Jamaludin, Md Zaini

PY - 2010

Y1 - 2010

N2 - The application of optical fiber sensor in fields such as heavy industries has to greater extent become very important as the optical sensors is immune to EMI. This paper presented a stable high pressure sensor using an erbium-doped fiber laser (EDFL). The pressure sensor head is made of fiber Bragg grating (FBG) encased in stainless steel housing to withstand high pressure of up to 10bar. The stability of the sensing system is measured over 30 minutes and the result shows about 1.50% and 0.41% variation of peak output power for ring and linear respectively. In addition, the wavelength variation for ring is 1.16% and there is no significant variation linear configuration.

AB - The application of optical fiber sensor in fields such as heavy industries has to greater extent become very important as the optical sensors is immune to EMI. This paper presented a stable high pressure sensor using an erbium-doped fiber laser (EDFL). The pressure sensor head is made of fiber Bragg grating (FBG) encased in stainless steel housing to withstand high pressure of up to 10bar. The stability of the sensing system is measured over 30 minutes and the result shows about 1.50% and 0.41% variation of peak output power for ring and linear respectively. In addition, the wavelength variation for ring is 1.16% and there is no significant variation linear configuration.

UR - http://www.scopus.com/inward/record.url?scp=79951978144&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951978144&partnerID=8YFLogxK

U2 - 10.1109/SCORED.2010.5704022

DO - 10.1109/SCORED.2010.5704022

M3 - Conference contribution

SN - 9781424486489

SP - 307

EP - 309

BT - Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering

ER -

Abdullah F, Idris SM, Al-Mansoori MH, Jamaludin MZ. Stability of erbium-doped fiber laser for high pressure measurement: Ring vs linear cavity. In Proceeding, 2010 IEEE Student Conference on Research and Development - Engineering: Innovation and Beyond, SCOReD 2010. 2010. p. 307-309. 5704022 https://doi.org/10.1109/SCORED.2010.5704022