Abstract

Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, »Cycle-Tempo» is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance.

Original languageEnglish
Article number012005
JournalIOP Conference Series: Earth and Environmental Science
Volume16
Issue number1
DOIs
Publication statusPublished - 01 Jan 2013
Event26th IAHR Symposium on Hydraulic Machinery and Systems - Beijing, China
Duration: 19 Aug 201223 Aug 2012

Fingerprint

power plant
gas
simulation
exergy
sheet flow
piping
temperature profile
ambient air
environmental factor
air temperature
thermodynamics
temperature
software
air
water
plant component
loss
station
stack

All Science Journal Classification (ASJC) codes

  • Environmental Science(all)
  • Earth and Planetary Sciences(all)

Cite this

@article{7eccb87d0f544df087b476537ce13ddf,
title = "Simulation of existing gas-fuelled conventional steam power plant using Cycle Tempo",
abstract = "Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, »Cycle-Tempo» is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance.",
author = "Jamel, {M. S.} and Rahman, {A. Abd} and Shamsuddin, {A. H.}",
year = "2013",
month = "1",
day = "1",
doi = "10.1088/1755-1315/16/1/012005",
language = "English",
volume = "16",
journal = "IOP Conference Series: Earth and Environmental Science",
issn = "1755-1307",
publisher = "IOP Publishing Ltd.",
number = "1",

}

Simulation of existing gas-fuelled conventional steam power plant using Cycle Tempo. / Jamel, M. S.; Rahman, A. Abd; Shamsuddin, A. H.

In: IOP Conference Series: Earth and Environmental Science, Vol. 16, No. 1, 012005, 01.01.2013.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Simulation of existing gas-fuelled conventional steam power plant using Cycle Tempo

AU - Jamel, M. S.

AU - Rahman, A. Abd

AU - Shamsuddin, A. H.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, »Cycle-Tempo» is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance.

AB - Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, »Cycle-Tempo» is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance.

UR - http://www.scopus.com/inward/record.url?scp=84881102288&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881102288&partnerID=8YFLogxK

U2 - 10.1088/1755-1315/16/1/012005

DO - 10.1088/1755-1315/16/1/012005

M3 - Conference article

AN - SCOPUS:84881102288

VL - 16

JO - IOP Conference Series: Earth and Environmental Science

JF - IOP Conference Series: Earth and Environmental Science

SN - 1755-1307

IS - 1

M1 - 012005

ER -