Abstract

The renewable energy (RE) sector has grown exponentially in Malaysia with the introduction of the Feed-In-Tariff (FIT) by the Ministry of Energy, Green Technology and Water. Photovoltaic, biogas, biomass and mini hydro are among the renewable energy sources which offer a lucrative tariff to incite developers in taking the green technology route. In order to receive the FIT, a developer is required by the utility company to perform a power system analysis which will determine the technical feasibility of an RE interconnection to the utility company's existing grid system. There are a number of aspects which the analysis looks at, the most important being the load flow and fault levels in the network after the introduction of an RE source. The analysis is done by modelling the utility company's existing network and simulating the network with the interconnection of an RE source. The results are then compared to the values before an interconnection is made as well as ensuring the voltage rise or the increase in fault levels do not violate any pre-existing regulations set by the utility company. This paper will delve into the mechanics of performing a load flow analysis and examining the results obtained.

Original languageEnglish
Article number012154
JournalIOP Conference Series: Earth and Environmental Science
Volume16
Issue number1
DOIs
Publication statusPublished - 01 Jan 2013
Event26th IAHR Symposium on Hydraulic Machinery and Systems - Beijing, China
Duration: 19 Aug 201223 Aug 2012

Fingerprint

energy
biogas
systems analysis
mechanics
biomass
modeling
analysis
renewable energy source
tariff
water
regulation
ministry

All Science Journal Classification (ASJC) codes

  • Environmental Science(all)
  • Earth and Planetary Sciences(all)

Cite this

@article{c12682e6ea6f418b88d3ea1f198cc857,
title = "Power system study for renewable energy interconnection in Malaysia",
abstract = "The renewable energy (RE) sector has grown exponentially in Malaysia with the introduction of the Feed-In-Tariff (FIT) by the Ministry of Energy, Green Technology and Water. Photovoltaic, biogas, biomass and mini hydro are among the renewable energy sources which offer a lucrative tariff to incite developers in taking the green technology route. In order to receive the FIT, a developer is required by the utility company to perform a power system analysis which will determine the technical feasibility of an RE interconnection to the utility company's existing grid system. There are a number of aspects which the analysis looks at, the most important being the load flow and fault levels in the network after the introduction of an RE source. The analysis is done by modelling the utility company's existing network and simulating the network with the interconnection of an RE source. The results are then compared to the values before an interconnection is made as well as ensuring the voltage rise or the increase in fault levels do not violate any pre-existing regulations set by the utility company. This paper will delve into the mechanics of performing a load flow analysis and examining the results obtained.",
author = "Askar, {O. F.} and Ramachandaramurthy, {V. K.}",
year = "2013",
month = "1",
day = "1",
doi = "10.1088/1755-1315/16/1/012154",
language = "English",
volume = "16",
journal = "IOP Conference Series: Earth and Environmental Science",
issn = "1755-1307",
publisher = "IOP Publishing Ltd.",
number = "1",

}

Power system study for renewable energy interconnection in Malaysia. / Askar, O. F.; Ramachandaramurthy, V. K.

In: IOP Conference Series: Earth and Environmental Science, Vol. 16, No. 1, 012154, 01.01.2013.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Power system study for renewable energy interconnection in Malaysia

AU - Askar, O. F.

AU - Ramachandaramurthy, V. K.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - The renewable energy (RE) sector has grown exponentially in Malaysia with the introduction of the Feed-In-Tariff (FIT) by the Ministry of Energy, Green Technology and Water. Photovoltaic, biogas, biomass and mini hydro are among the renewable energy sources which offer a lucrative tariff to incite developers in taking the green technology route. In order to receive the FIT, a developer is required by the utility company to perform a power system analysis which will determine the technical feasibility of an RE interconnection to the utility company's existing grid system. There are a number of aspects which the analysis looks at, the most important being the load flow and fault levels in the network after the introduction of an RE source. The analysis is done by modelling the utility company's existing network and simulating the network with the interconnection of an RE source. The results are then compared to the values before an interconnection is made as well as ensuring the voltage rise or the increase in fault levels do not violate any pre-existing regulations set by the utility company. This paper will delve into the mechanics of performing a load flow analysis and examining the results obtained.

AB - The renewable energy (RE) sector has grown exponentially in Malaysia with the introduction of the Feed-In-Tariff (FIT) by the Ministry of Energy, Green Technology and Water. Photovoltaic, biogas, biomass and mini hydro are among the renewable energy sources which offer a lucrative tariff to incite developers in taking the green technology route. In order to receive the FIT, a developer is required by the utility company to perform a power system analysis which will determine the technical feasibility of an RE interconnection to the utility company's existing grid system. There are a number of aspects which the analysis looks at, the most important being the load flow and fault levels in the network after the introduction of an RE source. The analysis is done by modelling the utility company's existing network and simulating the network with the interconnection of an RE source. The results are then compared to the values before an interconnection is made as well as ensuring the voltage rise or the increase in fault levels do not violate any pre-existing regulations set by the utility company. This paper will delve into the mechanics of performing a load flow analysis and examining the results obtained.

UR - http://www.scopus.com/inward/record.url?scp=84881117286&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881117286&partnerID=8YFLogxK

U2 - 10.1088/1755-1315/16/1/012154

DO - 10.1088/1755-1315/16/1/012154

M3 - Conference article

AN - SCOPUS:84881117286

VL - 16

JO - IOP Conference Series: Earth and Environmental Science

JF - IOP Conference Series: Earth and Environmental Science

SN - 1755-1307

IS - 1

M1 - 012154

ER -