This paper discusses on the implementation of a grid-connected PV system for university campus in Malaysia. The primary goal of this study is to develop a grid-connected microgrid comprises of Photovoltaic (PV) and a battery storage system to meet the campus load demand and minimize grid dependency. The microgrid modeled and simulated in Hybrid Optimization Model for Electrical Renewable (HOMER) software. Actual load profile and renewable resources were used as an input parameter for the hybrid system. The campus selected is Universiti Kuala Lumpur, British Malaysian Institute as it represents typical load profile for a small campus. Therefore, the results can be used to represent hybrid system development for other small campuses in Malaysia as well. Firstly, optimal sizing of renewable energy (RE) were simulated with respect to total Net Present Cost (NPC) and Cost of Energy (COE). Then, sensitivity analysis conducted to determine the system performance based on changes of load growth, and renewable resources. The results demonstrate optimal HRES combinations for the campus microgrid comprises of 50 kWp of PV generations with 50 kW inverter. However, inclusion of 576 kWh battery storage system will increase the NPC but has higher RE penetration.

Original languageEnglish
Pages (from-to)899-906
Number of pages8
JournalIndonesian Journal of Electrical Engineering and Computer Science
Volume12
Issue number3
DOIs
Publication statusPublished - Dec 2018

Fingerprint

Microgrid
Photovoltaic System
Grid
Hybrid systems
Renewable Resources
Malaysia
Renewable Energy
Storage System
Hybrid Systems
Battery
Costs
Sensitivity analysis
Hybrid Optimization
Inverter
Hybrid Model
System Development
Optimization Model
Penetration
Sensitivity Analysis
High Energy

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Information Systems
  • Hardware and Architecture
  • Computer Networks and Communications
  • Control and Optimization
  • Electrical and Electronic Engineering

Cite this

Reyasudin Basir Khan, M. ; Pasupuleti, Jagadeesh ; Al-Fattah, Jabbar ; Tahmasebi, Mehrdad. / Optimal grid-connected PV system for a campus microgrid. In: Indonesian Journal of Electrical Engineering and Computer Science. 2018 ; Vol. 12, No. 3. pp. 899-906.
@article{3a74326ba65d4ed6a1d12d2115f13a64,
title = "Optimal grid-connected PV system for a campus microgrid",
abstract = "This paper discusses on the implementation of a grid-connected PV system for university campus in Malaysia. The primary goal of this study is to develop a grid-connected microgrid comprises of Photovoltaic (PV) and a battery storage system to meet the campus load demand and minimize grid dependency. The microgrid modeled and simulated in Hybrid Optimization Model for Electrical Renewable (HOMER) software. Actual load profile and renewable resources were used as an input parameter for the hybrid system. The campus selected is Universiti Kuala Lumpur, British Malaysian Institute as it represents typical load profile for a small campus. Therefore, the results can be used to represent hybrid system development for other small campuses in Malaysia as well. Firstly, optimal sizing of renewable energy (RE) were simulated with respect to total Net Present Cost (NPC) and Cost of Energy (COE). Then, sensitivity analysis conducted to determine the system performance based on changes of load growth, and renewable resources. The results demonstrate optimal HRES combinations for the campus microgrid comprises of 50 kWp of PV generations with 50 kW inverter. However, inclusion of 576 kWh battery storage system will increase the NPC but has higher RE penetration.",
author = "{Reyasudin Basir Khan}, M. and Jagadeesh Pasupuleti and Jabbar Al-Fattah and Mehrdad Tahmasebi",
year = "2018",
month = "12",
doi = "10.11591/ijeecs.v12.i3.pp899-906",
language = "English",
volume = "12",
pages = "899--906",
journal = "Indonesian Journal of Electrical Engineering and Computer Science",
issn = "2502-4752",
publisher = "Institute of Advanced Engineering and Science (IAES)",
number = "3",

}

Optimal grid-connected PV system for a campus microgrid. / Reyasudin Basir Khan, M.; Pasupuleti, Jagadeesh; Al-Fattah, Jabbar; Tahmasebi, Mehrdad.

In: Indonesian Journal of Electrical Engineering and Computer Science, Vol. 12, No. 3, 12.2018, p. 899-906.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Optimal grid-connected PV system for a campus microgrid

AU - Reyasudin Basir Khan, M.

AU - Pasupuleti, Jagadeesh

AU - Al-Fattah, Jabbar

AU - Tahmasebi, Mehrdad

PY - 2018/12

Y1 - 2018/12

N2 - This paper discusses on the implementation of a grid-connected PV system for university campus in Malaysia. The primary goal of this study is to develop a grid-connected microgrid comprises of Photovoltaic (PV) and a battery storage system to meet the campus load demand and minimize grid dependency. The microgrid modeled and simulated in Hybrid Optimization Model for Electrical Renewable (HOMER) software. Actual load profile and renewable resources were used as an input parameter for the hybrid system. The campus selected is Universiti Kuala Lumpur, British Malaysian Institute as it represents typical load profile for a small campus. Therefore, the results can be used to represent hybrid system development for other small campuses in Malaysia as well. Firstly, optimal sizing of renewable energy (RE) were simulated with respect to total Net Present Cost (NPC) and Cost of Energy (COE). Then, sensitivity analysis conducted to determine the system performance based on changes of load growth, and renewable resources. The results demonstrate optimal HRES combinations for the campus microgrid comprises of 50 kWp of PV generations with 50 kW inverter. However, inclusion of 576 kWh battery storage system will increase the NPC but has higher RE penetration.

AB - This paper discusses on the implementation of a grid-connected PV system for university campus in Malaysia. The primary goal of this study is to develop a grid-connected microgrid comprises of Photovoltaic (PV) and a battery storage system to meet the campus load demand and minimize grid dependency. The microgrid modeled and simulated in Hybrid Optimization Model for Electrical Renewable (HOMER) software. Actual load profile and renewable resources were used as an input parameter for the hybrid system. The campus selected is Universiti Kuala Lumpur, British Malaysian Institute as it represents typical load profile for a small campus. Therefore, the results can be used to represent hybrid system development for other small campuses in Malaysia as well. Firstly, optimal sizing of renewable energy (RE) were simulated with respect to total Net Present Cost (NPC) and Cost of Energy (COE). Then, sensitivity analysis conducted to determine the system performance based on changes of load growth, and renewable resources. The results demonstrate optimal HRES combinations for the campus microgrid comprises of 50 kWp of PV generations with 50 kW inverter. However, inclusion of 576 kWh battery storage system will increase the NPC but has higher RE penetration.

UR - http://www.scopus.com/inward/record.url?scp=85057235951&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057235951&partnerID=8YFLogxK

U2 - 10.11591/ijeecs.v12.i3.pp899-906

DO - 10.11591/ijeecs.v12.i3.pp899-906

M3 - Article

AN - SCOPUS:85057235951

VL - 12

SP - 899

EP - 906

JO - Indonesian Journal of Electrical Engineering and Computer Science

JF - Indonesian Journal of Electrical Engineering and Computer Science

SN - 2502-4752

IS - 3

ER -