Multi-area economic dispatch by using differential evolution immunized ant colony optimization (DEIANT)

N. H. Marzuki, N. A. Rahmat, J. Mat Salleh, O. F. Otoh

Research output: Contribution to journalArticle

Abstract

Economic dispatch is an important issue within the electrical system in meeting the lowest cost of the system and is subject to transmission and operating constraints.The power system operation and planning economic dispatch required a reliable technique to achieve minimal cost in economic dispatch otherwise the objective to minimize the generation cost fail. The electrical transmission network does not make complete electricity generation in Single-area economic dispatch. Thus, to complete the economic dispatch for the power transmission system, the multi-area network is proposed. The Multi-Area Economic Dispatch(MAED) connects two or more areas through a tie-line. Each region has a specific cost and load pattern. Tie-lines are used as connectors to enable power switching between regions. 31-Bus test system tested using an algorithm known as Differential Evolution Immunized Ant Colony Optimization (DEIANT) with different case studies with several trials taken to assess the consistency of results. Comparative studies with Pre-Optimization and Newton Rap son revealed that DEIANT technique is more reliable for multi-area power system network.

Original languageEnglish
Pages (from-to)3525-3530
Number of pages6
JournalInternational Journal of Engineering and Advanced Technology
Volume9
Issue number1
DOIs
Publication statusPublished - Oct 2019

Fingerprint

Ant colony optimization
Economics
Costs
Electric power transmission networks
Power transmission
Electricity
Planning

All Science Journal Classification (ASJC) codes

  • Environmental Engineering
  • Engineering(all)
  • Computer Science Applications

Cite this

@article{c572f429d24749bea4445489a8502aa8,
title = "Multi-area economic dispatch by using differential evolution immunized ant colony optimization (DEIANT)",
abstract = "Economic dispatch is an important issue within the electrical system in meeting the lowest cost of the system and is subject to transmission and operating constraints.The power system operation and planning economic dispatch required a reliable technique to achieve minimal cost in economic dispatch otherwise the objective to minimize the generation cost fail. The electrical transmission network does not make complete electricity generation in Single-area economic dispatch. Thus, to complete the economic dispatch for the power transmission system, the multi-area network is proposed. The Multi-Area Economic Dispatch(MAED) connects two or more areas through a tie-line. Each region has a specific cost and load pattern. Tie-lines are used as connectors to enable power switching between regions. 31-Bus test system tested using an algorithm known as Differential Evolution Immunized Ant Colony Optimization (DEIANT) with different case studies with several trials taken to assess the consistency of results. Comparative studies with Pre-Optimization and Newton Rap son revealed that DEIANT technique is more reliable for multi-area power system network.",
author = "Marzuki, {N. H.} and Rahmat, {N. A.} and {Mat Salleh}, J. and Otoh, {O. F.}",
year = "2019",
month = "10",
doi = "10.35940/ijeat.A2680.109119",
language = "English",
volume = "9",
pages = "3525--3530",
journal = "International Journal of Engineering and Advanced Technology",
issn = "2249-8958",
publisher = "Blue Eyes Intelligence Engineering and Sciences Publication",
number = "1",

}

Multi-area economic dispatch by using differential evolution immunized ant colony optimization (DEIANT). / Marzuki, N. H.; Rahmat, N. A.; Mat Salleh, J.; Otoh, O. F.

In: International Journal of Engineering and Advanced Technology, Vol. 9, No. 1, 10.2019, p. 3525-3530.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Multi-area economic dispatch by using differential evolution immunized ant colony optimization (DEIANT)

AU - Marzuki, N. H.

AU - Rahmat, N. A.

AU - Mat Salleh, J.

AU - Otoh, O. F.

PY - 2019/10

Y1 - 2019/10

N2 - Economic dispatch is an important issue within the electrical system in meeting the lowest cost of the system and is subject to transmission and operating constraints.The power system operation and planning economic dispatch required a reliable technique to achieve minimal cost in economic dispatch otherwise the objective to minimize the generation cost fail. The electrical transmission network does not make complete electricity generation in Single-area economic dispatch. Thus, to complete the economic dispatch for the power transmission system, the multi-area network is proposed. The Multi-Area Economic Dispatch(MAED) connects two or more areas through a tie-line. Each region has a specific cost and load pattern. Tie-lines are used as connectors to enable power switching between regions. 31-Bus test system tested using an algorithm known as Differential Evolution Immunized Ant Colony Optimization (DEIANT) with different case studies with several trials taken to assess the consistency of results. Comparative studies with Pre-Optimization and Newton Rap son revealed that DEIANT technique is more reliable for multi-area power system network.

AB - Economic dispatch is an important issue within the electrical system in meeting the lowest cost of the system and is subject to transmission and operating constraints.The power system operation and planning economic dispatch required a reliable technique to achieve minimal cost in economic dispatch otherwise the objective to minimize the generation cost fail. The electrical transmission network does not make complete electricity generation in Single-area economic dispatch. Thus, to complete the economic dispatch for the power transmission system, the multi-area network is proposed. The Multi-Area Economic Dispatch(MAED) connects two or more areas through a tie-line. Each region has a specific cost and load pattern. Tie-lines are used as connectors to enable power switching between regions. 31-Bus test system tested using an algorithm known as Differential Evolution Immunized Ant Colony Optimization (DEIANT) with different case studies with several trials taken to assess the consistency of results. Comparative studies with Pre-Optimization and Newton Rap son revealed that DEIANT technique is more reliable for multi-area power system network.

UR - http://www.scopus.com/inward/record.url?scp=85074658668&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85074658668&partnerID=8YFLogxK

U2 - 10.35940/ijeat.A2680.109119

DO - 10.35940/ijeat.A2680.109119

M3 - Article

AN - SCOPUS:85074658668

VL - 9

SP - 3525

EP - 3530

JO - International Journal of Engineering and Advanced Technology

JF - International Journal of Engineering and Advanced Technology

SN - 2249-8958

IS - 1

ER -