Abstract
The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented.
Original language | English |
---|---|
Title of host publication | 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings |
Pages | 147-151 |
Number of pages | 5 |
DOIs | |
Publication status | Published - 01 Dec 2005 |
Event | 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Johor, Malaysia Duration: 20 Dec 2005 → 21 Dec 2005 |
Publication series
Name | 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings |
---|---|
Volume | 2005 |
Other
Other | 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 |
---|---|
Country | Malaysia |
City | Johor |
Period | 20/12/05 → 21/12/05 |
Fingerprint
All Science Journal Classification (ASJC) codes
- Engineering(all)
Cite this
}
Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements. / Rahman, N. A.; Hussain, H.; Said, I.; Jalal, T. S.; Farag, A. S.
2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings. 2005. p. 147-151 1607795 (2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings; Vol. 2005).Research output: Chapter in Book/Report/Conference proceeding › Conference contribution
TY - GEN
T1 - Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements
AU - Rahman, N. A.
AU - Hussain, H.
AU - Said, I.
AU - Jalal, T. S.
AU - Farag, A. S.
PY - 2005/12/1
Y1 - 2005/12/1
N2 - The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented.
AB - The last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented.
UR - http://www.scopus.com/inward/record.url?scp=33847330774&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33847330774&partnerID=8YFLogxK
U2 - 10.1109/APACE.2005.1607795
DO - 10.1109/APACE.2005.1607795
M3 - Conference contribution
AN - SCOPUS:33847330774
SN - 0780394313
SN - 9780780394315
T3 - 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings
SP - 147
EP - 151
BT - 2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings