InAs avalanche photodiodes for X-ray detection

Rajiv B. Gomes, Pin Jern Ker, Chee Hing Tan, John P.R. David, Jo Shien Ng

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Pulse height spectra were obtained by irradiating 55Fe radioactive X-ray source on an InAs n-i-p APD cooled to 77K. The full width half maximum (FWHM) of the detected photopeak at 5.9 keV improves with increasing reverse bias. The FWHM decreases rapidly with gain from 2 keV at M = 1 to ∼950eV at M = 5.2, improving the minimum detectable energy and resolution of the APD. The larger than expected FWHM is due to non-optimised packaging that leads to increased leakage current of the detector.

Original languageEnglish
Title of host publication2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages2071-2073
Number of pages3
ISBN (Print)9781467301183
DOIs
Publication statusPublished - 01 Jan 2011
Event2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 - Valencia, Spain
Duration: 23 Oct 201129 Oct 2011

Other

Other2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
CountrySpain
CityValencia
Period23/10/1129/10/11

Fingerprint

pamidronate
Avalanches
avalanches
photodiodes
X-Rays
Product Packaging
photopeak
x rays
pulse amplitude
packaging
leakage
detectors
indium arsenide

All Science Journal Classification (ASJC) codes

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Cite this

Gomes, R. B., Ker, P. J., Tan, C. H., David, J. P. R., & Ng, J. S. (2011). InAs avalanche photodiodes for X-ray detection. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 (pp. 2071-2073). [6154421] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/NSSMIC.2011.6154421
Gomes, Rajiv B. ; Ker, Pin Jern ; Tan, Chee Hing ; David, John P.R. ; Ng, Jo Shien. / InAs avalanche photodiodes for X-ray detection. 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. Institute of Electrical and Electronics Engineers Inc., 2011. pp. 2071-2073
@inproceedings{33a578fe8bdd4f1588263b0d2e67ff74,
title = "InAs avalanche photodiodes for X-ray detection",
abstract = "Pulse height spectra were obtained by irradiating 55Fe radioactive X-ray source on an InAs n-i-p APD cooled to 77K. The full width half maximum (FWHM) of the detected photopeak at 5.9 keV improves with increasing reverse bias. The FWHM decreases rapidly with gain from 2 keV at M = 1 to ∼950eV at M = 5.2, improving the minimum detectable energy and resolution of the APD. The larger than expected FWHM is due to non-optimised packaging that leads to increased leakage current of the detector.",
author = "Gomes, {Rajiv B.} and Ker, {Pin Jern} and Tan, {Chee Hing} and David, {John P.R.} and Ng, {Jo Shien}",
year = "2011",
month = "1",
day = "1",
doi = "10.1109/NSSMIC.2011.6154421",
language = "English",
isbn = "9781467301183",
pages = "2071--2073",
booktitle = "2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
address = "United States",

}

Gomes, RB, Ker, PJ, Tan, CH, David, JPR & Ng, JS 2011, InAs avalanche photodiodes for X-ray detection. in 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011., 6154421, Institute of Electrical and Electronics Engineers Inc., pp. 2071-2073, 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011, Valencia, Spain, 23/10/11. https://doi.org/10.1109/NSSMIC.2011.6154421

InAs avalanche photodiodes for X-ray detection. / Gomes, Rajiv B.; Ker, Pin Jern; Tan, Chee Hing; David, John P.R.; Ng, Jo Shien.

2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. Institute of Electrical and Electronics Engineers Inc., 2011. p. 2071-2073 6154421.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - InAs avalanche photodiodes for X-ray detection

AU - Gomes, Rajiv B.

AU - Ker, Pin Jern

AU - Tan, Chee Hing

AU - David, John P.R.

AU - Ng, Jo Shien

PY - 2011/1/1

Y1 - 2011/1/1

N2 - Pulse height spectra were obtained by irradiating 55Fe radioactive X-ray source on an InAs n-i-p APD cooled to 77K. The full width half maximum (FWHM) of the detected photopeak at 5.9 keV improves with increasing reverse bias. The FWHM decreases rapidly with gain from 2 keV at M = 1 to ∼950eV at M = 5.2, improving the minimum detectable energy and resolution of the APD. The larger than expected FWHM is due to non-optimised packaging that leads to increased leakage current of the detector.

AB - Pulse height spectra were obtained by irradiating 55Fe radioactive X-ray source on an InAs n-i-p APD cooled to 77K. The full width half maximum (FWHM) of the detected photopeak at 5.9 keV improves with increasing reverse bias. The FWHM decreases rapidly with gain from 2 keV at M = 1 to ∼950eV at M = 5.2, improving the minimum detectable energy and resolution of the APD. The larger than expected FWHM is due to non-optimised packaging that leads to increased leakage current of the detector.

UR - http://www.scopus.com/inward/record.url?scp=84858654889&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84858654889&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2011.6154421

DO - 10.1109/NSSMIC.2011.6154421

M3 - Conference contribution

SN - 9781467301183

SP - 2071

EP - 2073

BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Gomes RB, Ker PJ, Tan CH, David JPR, Ng JS. InAs avalanche photodiodes for X-ray detection. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. Institute of Electrical and Electronics Engineers Inc. 2011. p. 2071-2073. 6154421 https://doi.org/10.1109/NSSMIC.2011.6154421