III lead ECG pulse measurement sensor

Research output: Contribution to journalArticle

Abstract

Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

Original languageEnglish
Article number012047
JournalIOP Conference Series: Materials Science and Engineering
Volume88
Issue number1
DOIs
Publication statusPublished - 21 Sep 2015

Fingerprint

Electrocardiography
Sensors
Lead
Butterworth filters
Operational amplifiers
Bioelectric potentials
Tissue
Hardware
Costs

All Science Journal Classification (ASJC) codes

  • Engineering(all)
  • Materials Science(all)

Cite this

@article{4e3d135d7ea34c0486f3720e355b3d97,
title = "III lead ECG pulse measurement sensor",
abstract = "Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.",
author = "{K. Thangaraju}, Savithry and K. Munisamy",
year = "2015",
month = "9",
day = "21",
doi = "10.1088/1757-899X/88/1/0112047",
language = "English",
volume = "88",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

III lead ECG pulse measurement sensor. / K. Thangaraju, Savithry; Munisamy, K.

In: IOP Conference Series: Materials Science and Engineering, Vol. 88, No. 1, 012047, 21.09.2015.

Research output: Contribution to journalArticle

TY - JOUR

T1 - III lead ECG pulse measurement sensor

AU - K. Thangaraju, Savithry

AU - Munisamy, K.

PY - 2015/9/21

Y1 - 2015/9/21

N2 - Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

AB - Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

UR - http://www.scopus.com/inward/record.url?scp=84948390080&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84948390080&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/88/1/0112047

DO - 10.1088/1757-899X/88/1/0112047

M3 - Article

VL - 88

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012047