Double tuned filter design for harmonic mitigation in grid connected solar PV

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

Renewable energy plays a significant part in the power generation revolution in line with the future smart grid focus. In Malaysia, one of the largest, clean and green energy produced is the solar PV energy. With obvious increase of penetration by renewable energies especially solar energy, in years to come the grid system is capable to self-sustain as micro grid without heavily depending from fossil fuel source. As the power flow will no longer be a one-way route generation, power quality issues arises from these interconnection can be very damaging to the grid and distribution assets if not handled well especially on harmonic issues. This paper presents the implementation of Double-Tuned filter for harmonic attenuation in a test case grid model. The design of the proposed filters is validated by simulation results in PSCAD software. The results show that the improved design meets the standards parallel to the THD and individual harmonic limits.

Original languageEnglish
Title of host publicationConference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014
EditorsMohd Izhwan Muhamad, Mohammad Nawawi Seroji
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages293-297
Number of pages5
ISBN (Electronic)9781479972975
DOIs
Publication statusPublished - 17 Mar 2014
Event2014 IEEE International Conference on Power and Energy, PECon 2014 - Kuching, Sarawak, Malaysia
Duration: 01 Dec 201403 Dec 2014

Publication series

NameConference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014

Other

Other2014 IEEE International Conference on Power and Energy, PECon 2014
CountryMalaysia
CityKuching, Sarawak
Period01/12/1403/12/14

Fingerprint

Solar energy
Power quality
Fossil fuels
Power generation

All Science Journal Classification (ASJC) codes

  • Fuel Technology
  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Yong, B. H., & Ramachandaramurthy, V. K. (2014). Double tuned filter design for harmonic mitigation in grid connected solar PV. In M. I. Muhamad, & M. N. Seroji (Eds.), Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014 (pp. 293-297). [7062459] (Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/PECON.2014.7062459
Yong, B. H. ; Ramachandaramurthy, Vigna Kumaran. / Double tuned filter design for harmonic mitigation in grid connected solar PV. Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. editor / Mohd Izhwan Muhamad ; Mohammad Nawawi Seroji. Institute of Electrical and Electronics Engineers Inc., 2014. pp. 293-297 (Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014).
@inproceedings{95c97b1748794d3994d472289dd41f5e,
title = "Double tuned filter design for harmonic mitigation in grid connected solar PV",
abstract = "Renewable energy plays a significant part in the power generation revolution in line with the future smart grid focus. In Malaysia, one of the largest, clean and green energy produced is the solar PV energy. With obvious increase of penetration by renewable energies especially solar energy, in years to come the grid system is capable to self-sustain as micro grid without heavily depending from fossil fuel source. As the power flow will no longer be a one-way route generation, power quality issues arises from these interconnection can be very damaging to the grid and distribution assets if not handled well especially on harmonic issues. This paper presents the implementation of Double-Tuned filter for harmonic attenuation in a test case grid model. The design of the proposed filters is validated by simulation results in PSCAD software. The results show that the improved design meets the standards parallel to the THD and individual harmonic limits.",
author = "Yong, {B. H.} and Ramachandaramurthy, {Vigna Kumaran}",
year = "2014",
month = "3",
day = "17",
doi = "10.1109/PECON.2014.7062459",
language = "English",
series = "Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "293--297",
editor = "Muhamad, {Mohd Izhwan} and Seroji, {Mohammad Nawawi}",
booktitle = "Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014",
address = "United States",

}

Yong, BH & Ramachandaramurthy, VK 2014, Double tuned filter design for harmonic mitigation in grid connected solar PV. in MI Muhamad & MN Seroji (eds), Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014., 7062459, Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014, Institute of Electrical and Electronics Engineers Inc., pp. 293-297, 2014 IEEE International Conference on Power and Energy, PECon 2014, Kuching, Sarawak, Malaysia, 01/12/14. https://doi.org/10.1109/PECON.2014.7062459

Double tuned filter design for harmonic mitigation in grid connected solar PV. / Yong, B. H.; Ramachandaramurthy, Vigna Kumaran.

Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. ed. / Mohd Izhwan Muhamad; Mohammad Nawawi Seroji. Institute of Electrical and Electronics Engineers Inc., 2014. p. 293-297 7062459 (Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Double tuned filter design for harmonic mitigation in grid connected solar PV

AU - Yong, B. H.

AU - Ramachandaramurthy, Vigna Kumaran

PY - 2014/3/17

Y1 - 2014/3/17

N2 - Renewable energy plays a significant part in the power generation revolution in line with the future smart grid focus. In Malaysia, one of the largest, clean and green energy produced is the solar PV energy. With obvious increase of penetration by renewable energies especially solar energy, in years to come the grid system is capable to self-sustain as micro grid without heavily depending from fossil fuel source. As the power flow will no longer be a one-way route generation, power quality issues arises from these interconnection can be very damaging to the grid and distribution assets if not handled well especially on harmonic issues. This paper presents the implementation of Double-Tuned filter for harmonic attenuation in a test case grid model. The design of the proposed filters is validated by simulation results in PSCAD software. The results show that the improved design meets the standards parallel to the THD and individual harmonic limits.

AB - Renewable energy plays a significant part in the power generation revolution in line with the future smart grid focus. In Malaysia, one of the largest, clean and green energy produced is the solar PV energy. With obvious increase of penetration by renewable energies especially solar energy, in years to come the grid system is capable to self-sustain as micro grid without heavily depending from fossil fuel source. As the power flow will no longer be a one-way route generation, power quality issues arises from these interconnection can be very damaging to the grid and distribution assets if not handled well especially on harmonic issues. This paper presents the implementation of Double-Tuned filter for harmonic attenuation in a test case grid model. The design of the proposed filters is validated by simulation results in PSCAD software. The results show that the improved design meets the standards parallel to the THD and individual harmonic limits.

UR - http://www.scopus.com/inward/record.url?scp=84946685369&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946685369&partnerID=8YFLogxK

U2 - 10.1109/PECON.2014.7062459

DO - 10.1109/PECON.2014.7062459

M3 - Conference contribution

T3 - Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014

SP - 293

EP - 297

BT - Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014

A2 - Muhamad, Mohd Izhwan

A2 - Seroji, Mohammad Nawawi

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Yong BH, Ramachandaramurthy VK. Double tuned filter design for harmonic mitigation in grid connected solar PV. In Muhamad MI, Seroji MN, editors, Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014. Institute of Electrical and Electronics Engineers Inc. 2014. p. 293-297. 7062459. (Conference Proceeding - 2014 IEEE International Conference on Power and Energy, PECon 2014). https://doi.org/10.1109/PECON.2014.7062459