Abstract

This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.

Original languageEnglish
Article number745894
JournalScientific World Journal
Volume2014
DOIs
Publication statusPublished - 01 Jan 2014

Fingerprint

Cost benefit analysis
cost-benefit analysis
Lighting
Cost-Benefit Analysis
energy
Energy conservation
life cycle analysis
Electricity
Retrofitting
information technology
Potential energy
Life Cycle Stages
potential energy
Libraries
Information technology
Light emitting diodes
Life cycle
Profitability
electricity
Technology

All Science Journal Classification (ASJC) codes

  • Biochemistry, Genetics and Molecular Biology(all)
  • Environmental Science(all)

Cite this

@article{7deaa2d2c1c54b81a6c3fa73930e674a,
title = "Cost-benefit analysis and emission reduction of energy efficient lighting at the universiti tenaga nasional",
abstract = "This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10{\%} for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.",
author = "Ganandran, {G. S.B.} and Mahlia, {T.m. Indra} and Ong, {Hwai Chyuan} and B. Rismanchi and Chong, {W. T.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1155/2014/745894",
language = "English",
volume = "2014",
journal = "The Scientific World Journal",
issn = "2356-6140",
publisher = "Hindawi Publishing Corporation",

}

Cost-benefit analysis and emission reduction of energy efficient lighting at the universiti tenaga nasional. / Ganandran, G. S.B.; Mahlia, T.m. Indra; Ong, Hwai Chyuan; Rismanchi, B.; Chong, W. T.

In: Scientific World Journal, Vol. 2014, 745894, 01.01.2014.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Cost-benefit analysis and emission reduction of energy efficient lighting at the universiti tenaga nasional

AU - Ganandran, G. S.B.

AU - Mahlia, T.m. Indra

AU - Ong, Hwai Chyuan

AU - Rismanchi, B.

AU - Chong, W. T.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.

AB - This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.

UR - http://www.scopus.com/inward/record.url?scp=84929055236&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84929055236&partnerID=8YFLogxK

U2 - 10.1155/2014/745894

DO - 10.1155/2014/745894

M3 - Article

VL - 2014

JO - The Scientific World Journal

JF - The Scientific World Journal

SN - 2356-6140

M1 - 745894

ER -