Control of a battery supported dynamic voltage restorer

Vigna Kumaran Ramachandaramurthy, C. Fitzer, A. Arulampalam, C. Zhan, M. Barnes, N. Jenkins

Research output: Contribution to journalArticle

88 Citations (Scopus)

Abstract

Control of a dynamic voltage restorer (DVR) based on Space Vector PWM is described. The control algorithm is able to compensate for any type of voltage sag and uses a software phase-locked loop to track phase jumps during a fault. The control algorithm restores the depressed voltages to the same phase and magnitude as the nominal pre-sag voltages and then gradually tracks to the phase of the depressed voltages. Experimental results are shown to validate the control algorithm using a three-phase prototype with a power rating of 10 kVA.

Original languageEnglish
Pages (from-to)533-542
Number of pages10
JournalIEE Proceedings: Generation, Transmission and Distribution
Volume149
Issue number5
DOIs
Publication statusPublished - 01 Sep 2002

Fingerprint

Electric potential
Phase locked loops
Vector spaces
Pulse width modulation

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this

Ramachandaramurthy, Vigna Kumaran ; Fitzer, C. ; Arulampalam, A. ; Zhan, C. ; Barnes, M. ; Jenkins, N. / Control of a battery supported dynamic voltage restorer. In: IEE Proceedings: Generation, Transmission and Distribution. 2002 ; Vol. 149, No. 5. pp. 533-542.
@article{dbb85effb6bd485e89cabf4e22756bca,
title = "Control of a battery supported dynamic voltage restorer",
abstract = "Control of a dynamic voltage restorer (DVR) based on Space Vector PWM is described. The control algorithm is able to compensate for any type of voltage sag and uses a software phase-locked loop to track phase jumps during a fault. The control algorithm restores the depressed voltages to the same phase and magnitude as the nominal pre-sag voltages and then gradually tracks to the phase of the depressed voltages. Experimental results are shown to validate the control algorithm using a three-phase prototype with a power rating of 10 kVA.",
author = "Ramachandaramurthy, {Vigna Kumaran} and C. Fitzer and A. Arulampalam and C. Zhan and M. Barnes and N. Jenkins",
year = "2002",
month = "9",
day = "1",
doi = "10.1049/ip-gtd:20020658",
language = "English",
volume = "149",
pages = "533--542",
journal = "IEE Proceedings: Generation, Transmission and Distribution",
issn = "1350-2360",
publisher = "Institute of Electrical Engineers",
number = "5",

}

Control of a battery supported dynamic voltage restorer. / Ramachandaramurthy, Vigna Kumaran; Fitzer, C.; Arulampalam, A.; Zhan, C.; Barnes, M.; Jenkins, N.

In: IEE Proceedings: Generation, Transmission and Distribution, Vol. 149, No. 5, 01.09.2002, p. 533-542.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Control of a battery supported dynamic voltage restorer

AU - Ramachandaramurthy, Vigna Kumaran

AU - Fitzer, C.

AU - Arulampalam, A.

AU - Zhan, C.

AU - Barnes, M.

AU - Jenkins, N.

PY - 2002/9/1

Y1 - 2002/9/1

N2 - Control of a dynamic voltage restorer (DVR) based on Space Vector PWM is described. The control algorithm is able to compensate for any type of voltage sag and uses a software phase-locked loop to track phase jumps during a fault. The control algorithm restores the depressed voltages to the same phase and magnitude as the nominal pre-sag voltages and then gradually tracks to the phase of the depressed voltages. Experimental results are shown to validate the control algorithm using a three-phase prototype with a power rating of 10 kVA.

AB - Control of a dynamic voltage restorer (DVR) based on Space Vector PWM is described. The control algorithm is able to compensate for any type of voltage sag and uses a software phase-locked loop to track phase jumps during a fault. The control algorithm restores the depressed voltages to the same phase and magnitude as the nominal pre-sag voltages and then gradually tracks to the phase of the depressed voltages. Experimental results are shown to validate the control algorithm using a three-phase prototype with a power rating of 10 kVA.

UR - http://www.scopus.com/inward/record.url?scp=0036755322&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036755322&partnerID=8YFLogxK

U2 - 10.1049/ip-gtd:20020658

DO - 10.1049/ip-gtd:20020658

M3 - Article

VL - 149

SP - 533

EP - 542

JO - IEE Proceedings: Generation, Transmission and Distribution

JF - IEE Proceedings: Generation, Transmission and Distribution

SN - 1350-2360

IS - 5

ER -