CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time

Mohammad Shakir Nasif, Mohamed Fekry, Firas Basim Ismail

Research output: Contribution to journalArticle

Abstract

Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90°) to 60°, 30° and parallel to the flow (0°) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation.

Original languageEnglish
Pages (from-to)12919-12922
Number of pages4
JournalARPN Journal of Engineering and Applied Sciences
Volume11
Issue number22
Publication statusPublished - 01 Jan 2016

Fingerprint

Computational fluid dynamics
Fires
Chemical activation
Water
Pallets
Wood
Computer simulation
Gases
Experiments
Hot Temperature

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

@article{22f721c3e9ee47fe8c5045c3c62a1fab,
title = "CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time",
abstract = "Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90°) to 60°, 30° and parallel to the flow (0°) has resulted in increasing t sprinkler activation time by about 8{\%}, 84{\%}, and 163{\%} respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation.",
author = "Nasif, {Mohammad Shakir} and Mohamed Fekry and Ismail, {Firas Basim}",
year = "2016",
month = "1",
day = "1",
language = "English",
volume = "11",
pages = "12919--12922",
journal = "ARPN Journal of Engineering and Applied Sciences",
issn = "1819-6608",
publisher = "Asian Research Publishing Network (ARPN)",
number = "22",

}

CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time. / Nasif, Mohammad Shakir; Fekry, Mohamed; Ismail, Firas Basim.

In: ARPN Journal of Engineering and Applied Sciences, Vol. 11, No. 22, 01.01.2016, p. 12919-12922.

Research output: Contribution to journalArticle

TY - JOUR

T1 - CFD investigation on the effect of varying fire sprinkler orientation on sprinkler activation time

AU - Nasif, Mohammad Shakir

AU - Fekry, Mohamed

AU - Ismail, Firas Basim

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90°) to 60°, 30° and parallel to the flow (0°) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation.

AB - Water sprinkler system is considered one of the main water-based fire suppression systems. Due to the turbulent nature of fire, prediction of water sprinklers activation time required performing numerous experiments and tests to understand the nature of the parameters involved in changing the activation time. It was noticed that the angle where the sprinkler arms are oriented towards the hot gas jet resulting from a fire had a great impact on the activation time of the sprinkler. In this research the orientation of the sprinkler's arm was changed by using Computational Fluid Dynamics (CFD) simulation. It was found that changing the sprinkler arm angle from perpendicular to the flow (90°) to 60°, 30° and parallel to the flow (0°) has resulted in increasing t sprinkler activation time by about 8%, 84%, and 163% respectively. The effect of sprinkler activation time variation was investigated on stacked wood pallets heat release rate. It was found that with a parallel orientation the fire is allowed to grow 2.5 times more in terms of Heat Release Rate (HRR) than with perpendicular orientation.

UR - http://www.scopus.com/inward/record.url?scp=85007273692&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85007273692&partnerID=8YFLogxK

M3 - Article

VL - 11

SP - 12919

EP - 12922

JO - ARPN Journal of Engineering and Applied Sciences

JF - ARPN Journal of Engineering and Applied Sciences

SN - 1819-6608

IS - 22

ER -