Capacity assessment and design of CFRP-strengthened steel channel columns

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

This paper presents a design method (BS5950-5) to predict the allowable load carrying capacity of cold formed steel channel section strengthened by carbon fiber reformed polymer composites applied to the web of the beam. A specimen is presented to illustrate the proposed design approach. The validity of the proposed design method has been verified by comparing with the experimental test results. A series of compression tests were conducted on plain and CFRP strengthened steel sections of different geometries. This paper also contains the consequences obtained by comparing the strengths of plain and CFRP strengthened steel columns using compression test. The findings showed that the strength of CFRP strengthened steel columns were up to 10% greater than plain cold form steel sections.

Original languageEnglish
Pages (from-to)4255-4261
Number of pages7
JournalIndian Journal of Science and Technology
Volume6
Issue number4
Publication statusPublished - Apr 2013

Fingerprint

Carbon fiber reinforced plastics
Steel
Load limits
Carbon fibers
Geometry
Composite materials
Polymers

All Science Journal Classification (ASJC) codes

  • General

Cite this

@article{49ba2d82d97f47c0a2a75126856db116,
title = "Capacity assessment and design of CFRP-strengthened steel channel columns",
abstract = "This paper presents a design method (BS5950-5) to predict the allowable load carrying capacity of cold formed steel channel section strengthened by carbon fiber reformed polymer composites applied to the web of the beam. A specimen is presented to illustrate the proposed design approach. The validity of the proposed design method has been verified by comparing with the experimental test results. A series of compression tests were conducted on plain and CFRP strengthened steel sections of different geometries. This paper also contains the consequences obtained by comparing the strengths of plain and CFRP strengthened steel columns using compression test. The findings showed that the strength of CFRP strengthened steel columns were up to 10{\%} greater than plain cold form steel sections.",
author = "Sreedhar Kalavagunta and Sivakumar Naganathan and Mustapha, {Kamal Nasharuddin}",
year = "2013",
month = "4",
language = "English",
volume = "6",
pages = "4255--4261",
journal = "Indian Journal of Science and Technology",
issn = "0974-6846",
publisher = "Indian Society for Education and Environment",
number = "4",

}

Capacity assessment and design of CFRP-strengthened steel channel columns. / Kalavagunta, Sreedhar; Naganathan, Sivakumar; Mustapha, Kamal Nasharuddin.

In: Indian Journal of Science and Technology, Vol. 6, No. 4, 04.2013, p. 4255-4261.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Capacity assessment and design of CFRP-strengthened steel channel columns

AU - Kalavagunta, Sreedhar

AU - Naganathan, Sivakumar

AU - Mustapha, Kamal Nasharuddin

PY - 2013/4

Y1 - 2013/4

N2 - This paper presents a design method (BS5950-5) to predict the allowable load carrying capacity of cold formed steel channel section strengthened by carbon fiber reformed polymer composites applied to the web of the beam. A specimen is presented to illustrate the proposed design approach. The validity of the proposed design method has been verified by comparing with the experimental test results. A series of compression tests were conducted on plain and CFRP strengthened steel sections of different geometries. This paper also contains the consequences obtained by comparing the strengths of plain and CFRP strengthened steel columns using compression test. The findings showed that the strength of CFRP strengthened steel columns were up to 10% greater than plain cold form steel sections.

AB - This paper presents a design method (BS5950-5) to predict the allowable load carrying capacity of cold formed steel channel section strengthened by carbon fiber reformed polymer composites applied to the web of the beam. A specimen is presented to illustrate the proposed design approach. The validity of the proposed design method has been verified by comparing with the experimental test results. A series of compression tests were conducted on plain and CFRP strengthened steel sections of different geometries. This paper also contains the consequences obtained by comparing the strengths of plain and CFRP strengthened steel columns using compression test. The findings showed that the strength of CFRP strengthened steel columns were up to 10% greater than plain cold form steel sections.

UR - http://www.scopus.com/inward/record.url?scp=84877686112&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877686112&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84877686112

VL - 6

SP - 4255

EP - 4261

JO - Indian Journal of Science and Technology

JF - Indian Journal of Science and Technology

SN - 0974-6846

IS - 4