Autonomous localization of partial discharge sources within large transformer windings

Muhamad Safwan Abd. Rahman, P. L. Lewin, P. Rapisarda

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Partial discharge (PD) condition monitoring inside a HV transformer generally and particularly along a transformer winding has become an important research area with the ultimate aim of providing asset health information that enables maintenance and replacement processes to be carried out effectively. As far as PD activity inside transformer windings is concerned, an electrical detection method has been developed based on the use of radio frequency current transducers and subsequent digital signal processing of captured measurement data. A localization approach based on the measurement of currents at the bushing tap point and neutral to earth connection has been developed, with the assumption that different PD source locations will generate unique signal profiles in terms of the distribution of measured current energies with respect to both frequency and time. Therefore the technique presented is based on analysis of measured current energies associated with different frequencies. Principal Component Analysis (PCA) is then applied to reduce the dimensionality of the data, whilst minimizing lost information in the original dataset. This non-linear analysis of captured current data is not practicable for the field but the process can be represented through the use of three finite impulse response filters that have the ability to perform PD source localization automatically and are straightforward to implement in monitoring hardware.

Original languageEnglish
Article number7480674
Pages (from-to)1088-1098
Number of pages11
JournalIEEE Transactions on Dielectrics and Electrical Insulation
Volume23
Issue number2
DOIs
Publication statusPublished - 01 Apr 2016

Fingerprint

Transformer windings
Partial discharges
Bushings
FIR filters
Condition monitoring
Nonlinear analysis
Digital signal processing
Principal component analysis
Transducers
Earth (planet)
Health
Hardware
Monitoring

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this

@article{c7a90b698e8941e1a08847978afce390,
title = "Autonomous localization of partial discharge sources within large transformer windings",
abstract = "Partial discharge (PD) condition monitoring inside a HV transformer generally and particularly along a transformer winding has become an important research area with the ultimate aim of providing asset health information that enables maintenance and replacement processes to be carried out effectively. As far as PD activity inside transformer windings is concerned, an electrical detection method has been developed based on the use of radio frequency current transducers and subsequent digital signal processing of captured measurement data. A localization approach based on the measurement of currents at the bushing tap point and neutral to earth connection has been developed, with the assumption that different PD source locations will generate unique signal profiles in terms of the distribution of measured current energies with respect to both frequency and time. Therefore the technique presented is based on analysis of measured current energies associated with different frequencies. Principal Component Analysis (PCA) is then applied to reduce the dimensionality of the data, whilst minimizing lost information in the original dataset. This non-linear analysis of captured current data is not practicable for the field but the process can be represented through the use of three finite impulse response filters that have the ability to perform PD source localization automatically and are straightforward to implement in monitoring hardware.",
author = "{Abd. Rahman}, {Muhamad Safwan} and Lewin, {P. L.} and P. Rapisarda",
year = "2016",
month = "4",
day = "1",
doi = "10.1109/TDEI.2015.005070",
language = "English",
volume = "23",
pages = "1088--1098",
journal = "IEEE Transactions on Dielectrics and Electrical Insulation",
issn = "1070-9878",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

Autonomous localization of partial discharge sources within large transformer windings. / Abd. Rahman, Muhamad Safwan; Lewin, P. L.; Rapisarda, P.

In: IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 23, No. 2, 7480674, 01.04.2016, p. 1088-1098.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Autonomous localization of partial discharge sources within large transformer windings

AU - Abd. Rahman, Muhamad Safwan

AU - Lewin, P. L.

AU - Rapisarda, P.

PY - 2016/4/1

Y1 - 2016/4/1

N2 - Partial discharge (PD) condition monitoring inside a HV transformer generally and particularly along a transformer winding has become an important research area with the ultimate aim of providing asset health information that enables maintenance and replacement processes to be carried out effectively. As far as PD activity inside transformer windings is concerned, an electrical detection method has been developed based on the use of radio frequency current transducers and subsequent digital signal processing of captured measurement data. A localization approach based on the measurement of currents at the bushing tap point and neutral to earth connection has been developed, with the assumption that different PD source locations will generate unique signal profiles in terms of the distribution of measured current energies with respect to both frequency and time. Therefore the technique presented is based on analysis of measured current energies associated with different frequencies. Principal Component Analysis (PCA) is then applied to reduce the dimensionality of the data, whilst minimizing lost information in the original dataset. This non-linear analysis of captured current data is not practicable for the field but the process can be represented through the use of three finite impulse response filters that have the ability to perform PD source localization automatically and are straightforward to implement in monitoring hardware.

AB - Partial discharge (PD) condition monitoring inside a HV transformer generally and particularly along a transformer winding has become an important research area with the ultimate aim of providing asset health information that enables maintenance and replacement processes to be carried out effectively. As far as PD activity inside transformer windings is concerned, an electrical detection method has been developed based on the use of radio frequency current transducers and subsequent digital signal processing of captured measurement data. A localization approach based on the measurement of currents at the bushing tap point and neutral to earth connection has been developed, with the assumption that different PD source locations will generate unique signal profiles in terms of the distribution of measured current energies with respect to both frequency and time. Therefore the technique presented is based on analysis of measured current energies associated with different frequencies. Principal Component Analysis (PCA) is then applied to reduce the dimensionality of the data, whilst minimizing lost information in the original dataset. This non-linear analysis of captured current data is not practicable for the field but the process can be represented through the use of three finite impulse response filters that have the ability to perform PD source localization automatically and are straightforward to implement in monitoring hardware.

UR - http://www.scopus.com/inward/record.url?scp=84973472779&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84973472779&partnerID=8YFLogxK

U2 - 10.1109/TDEI.2015.005070

DO - 10.1109/TDEI.2015.005070

M3 - Article

VL - 23

SP - 1088

EP - 1098

JO - IEEE Transactions on Dielectrics and Electrical Insulation

JF - IEEE Transactions on Dielectrics and Electrical Insulation

SN - 1070-9878

IS - 2

M1 - 7480674

ER -