Analysis of MPLS-TP Network for Different Applications

N. Suhaimy, W. S. H. M. W. Ahmad, N. A M. Radzi, F. Abdullah, M. Z. Jamaludin, M. N. Zakaria

Research output: Contribution to journalArticle

Abstract

In the perspective of Multiprotocol Label Switching – Transport Profile (MPLS-TP) network, a reliable framework architecture or mechanism needs to be ascertained by comparing the results obtained through implementation of previously proposed scheme towards the network. This is important in order to implement an efficient system for different types of applications or services. Various results are reviewed and analyzed from the related works followed by detail discussions based on their proposed objectives. The analyses shown that most applications of MPLS-TP have been utilized for protection, followed by Operations, Administration and Maintenance (OAM), fairness and congestion control. This is due to the mission-critical operational service of protection which require us to meet the standard protection switching time of 50 ms.   
Original languageEnglish
Pages (from-to)892
JournalInternational Journal of Engineering and Technology
Volume7
Issue number4.35
DOIs
Publication statusPublished - 30 Nov 2018

Fingerprint

Labels

Cite this

@article{6a7ecd85fb154204a4c877d1610e4774,
title = "Analysis of MPLS-TP Network for Different Applications",
abstract = "In the perspective of Multiprotocol Label Switching – Transport Profile (MPLS-TP) network, a reliable framework architecture or mechanism needs to be ascertained by comparing the results obtained through implementation of previously proposed scheme towards the network. This is important in order to implement an efficient system for different types of applications or services. Various results are reviewed and analyzed from the related works followed by detail discussions based on their proposed objectives. The analyses shown that most applications of MPLS-TP have been utilized for protection, followed by Operations, Administration and Maintenance (OAM), fairness and congestion control. This is due to the mission-critical operational service of protection which require us to meet the standard protection switching time of 50 ms.   ",
author = "N. Suhaimy and {S. H. M. W. Ahmad}, W. and {A M. Radzi}, N. and F. Abdullah and {Z. Jamaludin}, M. and {N. Zakaria}, M.",
year = "2018",
month = "11",
day = "30",
doi = "10.14419/ijet.v7i4.35.26277",
language = "English",
volume = "7",
pages = "892",
journal = "International Journal of Engineering and Technology",
issn = "2319-8613",
publisher = "Engg Journals Publications",
number = "4.35",

}

Analysis of MPLS-TP Network for Different Applications. / Suhaimy, N.; S. H. M. W. Ahmad, W.; A M. Radzi, N.; Abdullah, F.; Z. Jamaludin, M.; N. Zakaria, M.

In: International Journal of Engineering and Technology, Vol. 7, No. 4.35, 30.11.2018, p. 892.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Analysis of MPLS-TP Network for Different Applications

AU - Suhaimy, N.

AU - S. H. M. W. Ahmad, W.

AU - A M. Radzi, N.

AU - Abdullah, F.

AU - Z. Jamaludin, M.

AU - N. Zakaria, M.

PY - 2018/11/30

Y1 - 2018/11/30

N2 - In the perspective of Multiprotocol Label Switching – Transport Profile (MPLS-TP) network, a reliable framework architecture or mechanism needs to be ascertained by comparing the results obtained through implementation of previously proposed scheme towards the network. This is important in order to implement an efficient system for different types of applications or services. Various results are reviewed and analyzed from the related works followed by detail discussions based on their proposed objectives. The analyses shown that most applications of MPLS-TP have been utilized for protection, followed by Operations, Administration and Maintenance (OAM), fairness and congestion control. This is due to the mission-critical operational service of protection which require us to meet the standard protection switching time of 50 ms.   

AB - In the perspective of Multiprotocol Label Switching – Transport Profile (MPLS-TP) network, a reliable framework architecture or mechanism needs to be ascertained by comparing the results obtained through implementation of previously proposed scheme towards the network. This is important in order to implement an efficient system for different types of applications or services. Various results are reviewed and analyzed from the related works followed by detail discussions based on their proposed objectives. The analyses shown that most applications of MPLS-TP have been utilized for protection, followed by Operations, Administration and Maintenance (OAM), fairness and congestion control. This is due to the mission-critical operational service of protection which require us to meet the standard protection switching time of 50 ms.   

UR - http://www.mendeley.com/research/analysis-mplstp-network-different-applications

U2 - 10.14419/ijet.v7i4.35.26277

DO - 10.14419/ijet.v7i4.35.26277

M3 - Article

VL - 7

SP - 892

JO - International Journal of Engineering and Technology

JF - International Journal of Engineering and Technology

SN - 2319-8613

IS - 4.35

ER -