This paper presents a new approach for controlling the secondary load bank of a micro-hydropower system using a fuzzy self-tuning proportional-derivative (PD) controller. This technology is designed in order to optimize the micro-hydropower system in a resort island located in the South China Sea. Thus, this technology will be able to mitigate the diesel fuel consumption and cost of electricity supply on the island. The optimal hydropower generation for this system depends on the available stream flow at the potential sites. At low stream flow, both the micro-hydropower system and the currently installed diesel generators are required to feed the load. However, when the hydropower generation exceeds the load demand, the diesel generator is shut down. Meanwhile, the system frequency is controlled by a secondary load bank that absorbs the hydropower which exceeds the consumer demand. The fuzzy rules were designed to automatically tune the PD gains under dynamic frequency variations. Performances of the fuzzy self-tuning PD controller were compared with the conventional PD controller. The result of the controller implementation shows the viability of the proposed new controller in achieving a higher performance and more robust load frequency control than the conventional PD controller.

Original languageEnglish
Article number012002
JournalIOP Conference Series: Earth and Environmental Science
Volume32
Issue number1
DOIs
Publication statusPublished - 19 Apr 2016

Fingerprint

diesel
streamflow
electricity supply
fuel consumption
low flow
viability
cost
demand
diesel fuel

All Science Journal Classification (ASJC) codes

  • Environmental Science(all)
  • Earth and Planetary Sciences(all)

Cite this

@article{f3d16e3642dc466eb7df6356404ba6c4,
title = "A new fuzzy self-tuning PD load frequency controller for micro-hydropower system",
abstract = "This paper presents a new approach for controlling the secondary load bank of a micro-hydropower system using a fuzzy self-tuning proportional-derivative (PD) controller. This technology is designed in order to optimize the micro-hydropower system in a resort island located in the South China Sea. Thus, this technology will be able to mitigate the diesel fuel consumption and cost of electricity supply on the island. The optimal hydropower generation for this system depends on the available stream flow at the potential sites. At low stream flow, both the micro-hydropower system and the currently installed diesel generators are required to feed the load. However, when the hydropower generation exceeds the load demand, the diesel generator is shut down. Meanwhile, the system frequency is controlled by a secondary load bank that absorbs the hydropower which exceeds the consumer demand. The fuzzy rules were designed to automatically tune the PD gains under dynamic frequency variations. Performances of the fuzzy self-tuning PD controller were compared with the conventional PD controller. The result of the controller implementation shows the viability of the proposed new controller in achieving a higher performance and more robust load frequency control than the conventional PD controller.",
author = "{Basir Khan}, {M. Reyasudin} and Razali Jidin and Pasupuleti Jagadeesh",
year = "2016",
month = "4",
day = "19",
doi = "10.1088/1755-1315/32/1/012002",
language = "English",
volume = "32",
journal = "IOP Conference Series: Earth and Environmental Science",
issn = "1755-1307",
publisher = "IOP Publishing Ltd.",
number = "1",

}

A new fuzzy self-tuning PD load frequency controller for micro-hydropower system. / Basir Khan, M. Reyasudin; Jidin, Razali; Jagadeesh, Pasupuleti.

In: IOP Conference Series: Earth and Environmental Science, Vol. 32, No. 1, 012002, 19.04.2016.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A new fuzzy self-tuning PD load frequency controller for micro-hydropower system

AU - Basir Khan, M. Reyasudin

AU - Jidin, Razali

AU - Jagadeesh, Pasupuleti

PY - 2016/4/19

Y1 - 2016/4/19

N2 - This paper presents a new approach for controlling the secondary load bank of a micro-hydropower system using a fuzzy self-tuning proportional-derivative (PD) controller. This technology is designed in order to optimize the micro-hydropower system in a resort island located in the South China Sea. Thus, this technology will be able to mitigate the diesel fuel consumption and cost of electricity supply on the island. The optimal hydropower generation for this system depends on the available stream flow at the potential sites. At low stream flow, both the micro-hydropower system and the currently installed diesel generators are required to feed the load. However, when the hydropower generation exceeds the load demand, the diesel generator is shut down. Meanwhile, the system frequency is controlled by a secondary load bank that absorbs the hydropower which exceeds the consumer demand. The fuzzy rules were designed to automatically tune the PD gains under dynamic frequency variations. Performances of the fuzzy self-tuning PD controller were compared with the conventional PD controller. The result of the controller implementation shows the viability of the proposed new controller in achieving a higher performance and more robust load frequency control than the conventional PD controller.

AB - This paper presents a new approach for controlling the secondary load bank of a micro-hydropower system using a fuzzy self-tuning proportional-derivative (PD) controller. This technology is designed in order to optimize the micro-hydropower system in a resort island located in the South China Sea. Thus, this technology will be able to mitigate the diesel fuel consumption and cost of electricity supply on the island. The optimal hydropower generation for this system depends on the available stream flow at the potential sites. At low stream flow, both the micro-hydropower system and the currently installed diesel generators are required to feed the load. However, when the hydropower generation exceeds the load demand, the diesel generator is shut down. Meanwhile, the system frequency is controlled by a secondary load bank that absorbs the hydropower which exceeds the consumer demand. The fuzzy rules were designed to automatically tune the PD gains under dynamic frequency variations. Performances of the fuzzy self-tuning PD controller were compared with the conventional PD controller. The result of the controller implementation shows the viability of the proposed new controller in achieving a higher performance and more robust load frequency control than the conventional PD controller.

UR - http://www.scopus.com/inward/record.url?scp=84966569716&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84966569716&partnerID=8YFLogxK

U2 - 10.1088/1755-1315/32/1/012002

DO - 10.1088/1755-1315/32/1/012002

M3 - Article

VL - 32

JO - IOP Conference Series: Earth and Environmental Science

JF - IOP Conference Series: Earth and Environmental Science

SN - 1755-1307

IS - 1

M1 - 012002

ER -